您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
-
我的賬號
註冊
登錄
忘記密碼?
回饋
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
CAD模型
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
CAD模型
登錄
註冊
忘記密碼?
回饋
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
Catalog navigation
所有產品目錄
幾何搜索
草圖搜索
變量搜索
可提供的產品目錄語言:
Deutsch
English
English
3RU21161KJ0
SIEMENS
Electric engineering, automation, process control engineering
Low-voltage switch technology
Overload protection device
Powered by
CAD模型選擇
生成CAD模型
生成PDF資料表
{siemens/27/27-37/27-37-15/27-37-15-01.prj},{NB=3RU21161KJ0},{MANUID=3RU21161KJ0},{AAB218=9.00},{AAB548=12.50},{AAP349=0},{AAP351=1},{AAP352=1},{AAS574=12.50},{AAS575=2.2},{BAD346=-99999},{NOCUPEROU=1},{PRICEQUANTITY=MIN},{QUANTITYMIN=1},{QUANTITYINT=1},{CTC=85364900},{SUPPLIERALTNO=3RU2116-1KJ0},{IMAGE=../../../_pool_/cd/e6/g_nsa0_xx_93011p.png},{DESCSHORT=Overload relay 9.0-12.5 A motor protection S00, Class 10, contactor mounting},{DESCLONG=Overload relay 9.0...12.5 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Ring cable lug Auxiliary circuit: ring cable lug Manual-Automatic-Reset},{EAN=4011209782549},{MANUNAME=Siemens}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
添加用於比較
可提供的產品: 120
HELP_VARIABLE
Company
SIEMENS
Description
Thermal overload relay
Bill of material
3RU21161KJ0
MANUID
Product number of the Manufacturer
3RU21161KJ0
3RU21161KJ0
SUPPLIERALTNO
Alternative product number
3RU2116-1KJ0
3RU2116-1KJ0
IMAGE
image
DESCSHORT
Short Description
Overload relay 9.0-12.5 A motor protection S00, Class 10, contactor mounting
Overload relay 9.0-12.5 A motor protection S00, Class 10, contactor mounting
DESCLONG
Long Description
Overload relay 9.0...12.5 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Ring cable lug Auxiliary circuit: ring cable lug Manual-Automatic-Reset
Overload relay 9.0...12.5 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Ring cable lug Auxiliary circuit: ring cable lug Manual-Automatic-Reset
EAN
4011209782549
4011209782549
MANUNAME
Manufacturer Name
Siemens
MANUTYPEDESC
Manufacturer Type Description
Overload relay 9.0...12.5 A Thermal For motor protection Size S00, Class 1
Overload relay 9.0...12.5 A Thermal For motor protection Size S00, Class 1
AAB218
Lowest value adjustable current range
9.00
9.00
A
AAB438
Release class
CLASS 10
AAB548
Greatest value adjustable current range
12.50
12.50
A
AAB667
suitable for mounting onto standard rails
false
AAP349
Number of auxiliary contacts as changer
0
AAP351
Number of auxiliary contacts as opener
1
AAP352
Number of auxiliary contacts as shutter
1
AAS574
Rated current [In] for the power loss specification
12.50
12.50
A
AAS575
Power loss per pole, current-dependent [PlIp]
2.2
2.2
W
BAC378
Connection type
Ring cable connection
Ring cable connection
BAD346
External reset possible
-99999
-99999
BAG640
Assembly type
Miscellaneous
NOCUPEROU
Number of content units per order unit
1
PRICEQUANTITY
Price Quantity
QUANTITYMIN
Minimum Order Quantity
1
QUANTITYINT
Quantity Scale
1
COO
Country of origin
DE
CTC
Customs tariff number
85364900
LINK_TO_INDUSTRY_MALL
Link to Industry Mall
Link to Industry Mall
REACH_INFORMATION
REACH information
REACH information
LINK_TO_TECHNICAL_DATA_SHEET
Link to technical data sheet
Link to technical data sheet
LINK_TO_3D_IMAGE
Link to 3D Image
Link to 3D Image
LINK_TO_SIEMENS_SUPPORT_PORTAL
Link to Siemens Support Portal
Link to Siemens Support Portal
LINK_TO_PRODUCT_PAGE
Link to Product Page
Link to Product Page
LINK_TO_APPLICATION_EXAMPLE
Link to Application example
Link to Application example
LINK_TO_SALES_BROCHURE
Link to Sales brochure
Link to Sales brochure
LINK_TO_CERTIFICATES
Link to Certificates
Link to Certificates
LINK_TO_DOWNLOAD
Link to Download
Link to Download
LINK_TO_FAQ
Link to FAQ
Link to FAQ
LINK_TO_MANUAL
Link to Manual
Link to Manual
LINK_TO_PRODUCT_NOTE
Link to product note
Link to product note
LINK_TO_TECHNICAL_DATA
Link to Technical data
Link to Technical data
Additional Information
CNS
Object Properties:
Order Number:
3RU21161KJ0
eclass
27-37-15-01 - Thermal overload relay:
Lowest value adjustable current range:
9
A
Release class:
CLASS 10
Greatest value adjustable current range:
12.5
A
suitable for mounting onto standard rails:
false
Number of auxiliary contacts as changer:
0
Number of auxiliary contacts as opener:
1
Number of auxiliary contacts as shutter:
1
Rated current [In] for the power loss specification:
12.5
A
Power loss per pole, current-dependent [PlIp]:
2.2
W
Connection type:
Ring cable connection
External reset possible:
-99999
Assembly type:
Miscellaneous
Preview - Generation
預覽
生成CAD模型
生成PDF資料表
3D
尺寸